The ES40 and ES20 signal converters simplify the management of the control logic and of the supply circuits for the electrovalve, transforming the output signal on the PLC into a voltage value not influenced by the supply voltage fluctuations, suitable for controlling a proportional hydraulic bidirectional valve.
ES40
The converter transforms the 6-bit binary value applied on the digital inputs into a voltage suitable for controlling a proportional hydraulic bidirectional valve.
Using the regulation trimmers it is possible to set the operative range accurately.
Power supply voltage Vdc. 24 (+/- 25%)
6 digital Inputs PNP Vdc. 24 with status led
Output voltage for electrovalve control, range 25% - 75% of the Vdc.
Sizes: mm. 100 (h) * 23 (l) * 120 (d)
ES20
The converter transforms the voltage (0-10 V range) on the inputs into an output voltage suitable for controlling a proportional hydraulic bidirectional valve.
The safety circuit checks the input voltage, activating the error output and
bringing the output back to 50% of the supply voltage in case of anomalies. An enable input and two emergency inputs for manual operations complete the control logic.
Power supply voltage Vdc. 24 (+/- 25%)
Ref voltage input 0-10 Volt
2 digital Inputs PNP Vdc. 24 with status led
Output voltage for electrovalve control, range 25% - 50% - 75% of the Vdc.
Output PNP Vdc. 24 for error signal
Output adjustment trimmer for emergency operations